Installation Procedure
IMPORTANT:
The following sequence MUST be followed. Make sure to hand tighten ONLY in the sequence specified and DO NOT apply any clamping force.
- Install the steering column to the vehicle and start the steering column nuts (3, 4) and bolts (1, 2) by hand using the following sequence:
- Place the steering column in place.
- Hand start the steering column nuts (3, 4).
- Hand start the steering column bolts (1, 2).
- Hold the steering column flush against the instrument panel carrier.
- Hand tighten steering column nut (3).
- Hand tighten steering column nut (4).
- Hand tighten steering column bolt (1).
- Hand tighten steering column bolt (2).
NOTE: Refer to Fastener Notice .IMPORTANT: The following torque sequence MUST be followed. - Tighten the steering column nuts (3, 4) and bolts (1, 2) in the following sequence:
- Tighten steering column nut (3).
Tighten: Tighten the nut to 27 N.m (20 lb ft).
- Tighten steering column nut (4).
Tighten: Tighten the nut to 27 N.m (20 lb ft).
- Tighten steering column bolt (1).
Tighten: Tighten the bolt to 27 N.m (20 lb ft).
- Tighten steering column bolt (2).
Tighten: Tighten the bolt to 27 N.m (20 lb ft).
- Tighten steering column nut (3).
- Install the intermediate steering shaft (2) and intermediate steering shaft bolt (1). Make sure the intermediate steering shaft upper seal (3) is seated correctly.
- If equipped, install the steering column lower support brace (2) and steering column lower support brace bolts (1).
Tighten: Tighten the bolt to 10 N.m (89 lb in).
- Connect all electrical connectors as needed.
- Install the steering column opening filler bolts. Refer to Steering Column Opening Filler Replacement .
- Install the instrument panel cluster trim plate bezel. Refer to Instrument Panel Cluster Trim Plate Bezel Replacement .
- Install the knee bolster. Refer to Knee Bolster Replacement .
- Install the left side instrument panel insulator panel. Refer to Instrument Panel Insulator Panel Replacement - Left Side .