Removal Procedure
- Disable the SIR System. Refer to SIR Disabling and Enabling Zone 1 .
- Remove the radio. Refer to Radio Replacement (RPO Code UM6, UM7) or Radio Replacement (RPO Code UC6) in Entertainment.
- Remove the I/P storage compartment door. Refer to Door Replacement - Instrument Panel (I/P) Compartment in Instrument Panel, Gages, and Console.
- Remove the fasteners (4,5) that retain inflatable restraint module to the instrument panel.
- Remove the inflatable restraint module (2) from the instrument panel (3).
- Fully deploy the module before disposal. If the module was replaced under warranty, fully deploy and dispose of the module after the required retention period. Refer to Inflator Module Handling and Scrapping .
CAUTION:
Refer to SIR Caution
in Cautions and Notices.
CAUTION:
Refer to SIR Inflator Module Handling and Storage Caution
in Cautions and Notices.