LEMON Manuals: Even more car manuals for everyone
Home >> GMC >> 2004 >> Sierra 2500 HD, 2D Pickup, 6.6 2, RWD, Standard >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - 6.6L (LLY) (Introduction) >> Repair Instructions >> Turbocharger Vane Position Sensor Replacement >> Installation Procedure

Installation Procedure

    Fig 1: View Of Turbocharger Vane Position Sensor And Electrical Connector
    GM1334926Courtesy of GENERAL MOTORS CORP.
    NOTE: Refer to Fastener Notice in Cautions and Notices.
  1. Install the turbocharger vane position sensor to the turbocharger.

    Tighten:  Tighten the sensor to 28 N.m (21 lb ft).

  2. Install the turbocharger vane position sensor connector to the bracket.
  3. Connect the turbocharger vane position sensor electrical connector.
  4. Install the thermal reflective shield/tape, refer to the following procedure.