Use the extended method when the original urethane adhesive bead left on the window opening pinchweld flange (after window removal) cannot serve as a base for the new window, or in any case where the use of the short method is in doubt.

This method includes the following cases:

No mounds or loose pieces of urethane adhesive should remain on the pinchweld flange. Do not remove all traces of urethane adhesive.

IMPORTANT:
  • If corrosion of the pinchweld flange is present, or if sheet metal repairs or replacements are required, refinish the pinchweld flange in order to present a clean, primer-only surface.
  • If paint repairs are required, mask the flange bonding area (prior to applying the color coat) in order to provide a clean, primer-only surface.
  • Appropriate materials for these primer applications are typically 2 component catalyzed products. Use materials such as BASF DE17®, DuPont 2610®, Sherwin-Williams PSE 4600 and NP70® and Martin-Semour 5120 and 5130®. Follow the manufacturer's directions for the mix, the application, and the drying times.
  • After repairing the opening as indicated, shake the pinchweld primer (black #3) well. Using a new dauber, apply the primer to the primed surface of the flange in the bonding area. Allow the primer to dry for 10 minutes.
  • Use the extended method of replacement and the appropriate urethane bead size when installing the window.