Oxygen Sensor: Installation
WARNING: This page is about a different variant/trim than selected.
- Whenever oxygen sensor is removed, coat threads with anti-seize compound before reinstalling. New oxygen sensors already have this compound applied to threads.
- Install oxygen sensor in exhaust pipe and tighten sensor to 30 ft. lbs. (41 N.m). Reconnect harness connector to oxygen sensor. Reconnect negative battery cable.