Left Power Mirror Does Not Operate In Left/Right Positions
- Using test light, backprobe between power mirror switch terminals "D" (Yellow wire) and "B" (Light Blue wire). Move power mirror switch to left and right positions. If test light illuminates in both positions, go to next step. If test light does not illuminate in one or both positions, replace power mirror switch.
- Backprobe between power mirror connector terminals "A" (Yellow wire) and "D" (Light Blue wire). Move power mirror switch to left and right positions. If test light illuminates in both positions, replace power mirror. If test light does not illuminate in both positions, repair open in Yellow or Light Blue wire between power mirror switch connector and power mirror connector.