Pull-In Windings
Using solenoid test connections shown in illustration, decrease battery voltage to 5 volts. See Fig 1. Refer to SOLENOID PULL-IN WINDING SPECIFICATIONS TABLE for correct amperage draw. A higher reading indicates windings are shorted or grounded; a lower reading indicates excessive resistance.
NOTE:
To prevent overheating of pull-in windings, DO NOT
energize for more than 15 seconds. Current draw will decrease as winding temperature increases.
SOLENOID PULL-IN WINDING SPECIFICATIONS
| Part No. | Amps | Volts |
|---|---|---|
| 1114520 | 23-30 | 5 |
| 1114530 | 23-30 | 5 |
| 1114563 | 26-30 | 5 |
| 10469039 | 31-36 | 5 |