SOLENOID HOLD-IN WINDING SPECIFICATIONS

Part No. Amps Volts
1114247 15-17 10
1114520, 1114530, 1114531 13-19 10
1114558 15-17 10
1114563 14-18 10
PMGR Solenoid 13-15 10
SOLENOID PULL-IN WINDING SPECIFICATIONS

Part. No. Amps Volts
1114247, 1114558 13-16 5
1114520, 1114530, 1114531 23-30 5
1114563 26-30 5
PMGR Solenoid 31-36 5
STARTER NO-LOAD SPECIFICATIONS

Part No. Series Amps (1) RPM
1998530 5MT 50-75 6000-11,900
10455016 5MT 50-75 6500-11,900
10455018 5MT 50-75 6500-11,900
1998559 10MT 60-90 6500-10,500
1998583 10MT 70-110 6500-10,700
1998584 10MT 70-110 6500-10,700
1998588 10MT 70-110 6500-10,700
1998589 10MT 70-110 6500-10,700
1998590 10MT 70-110 6500-10,700
1113589 27MT 120-210 9000-13,400
1113590 27MT 120-210 9000-13,400
9000719 PMGR 50-90 2300-26,600
9000735 PMGR 50-90 2300-26,600
(1) RPM specification given for PMGR starter is drive speed.