Power Liftgate Initialization

For information on Ford Color Coded Illustrations refer to OEM COLOR CODING .

Programming 

NOTE: This procedure clears and then sets new open and close end points in the RGTM memory.
  1. Turn the ignition ON.
  2. Using a scan tool perform the RGTM self test to complete power liftgate initialization. From the diagnostic scan tool, enter TOOLBOX > Self Test > RGTM > Run Selected Procedure.