Auto-Start-Stop Accumulator: Installation
- Material: Petroleum jelly Install and lubricate the start/stop accumulator O-rings with petroleum jelly.
-
NOTE: To prevent O-ring damage, fully seat the start/stop accumulator before installing the bolts.
Install the start/stop accumulator, bolts and studbolt.
Torque : 18 lb.ft (25 Nm)
- Connect the start/stop accumulator electrical connector.
- Remove the hook and position back the coolant valve and hoses, install the nuts.
Torque : 106 lb.in (12 Nm)
- Install the battery tray support bracket, nut and bolt.
Torque : 177 lb.in (20 Nm)
- Install the battery tray. Refer to: BATTERY TRAY .
- Check the transmission fluid level. Refer to: Transmission Fluid Level Check .