LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2020 >> F-450 Super Duty Limited >> Repair and Diagnosis >> Electrical >> Charging Systems >> Generator And Regulator >> Specifications >> General Specifications

General Specifications

Item Specification
6.2L V8 - Base Heavy Duty 
Rating 157 amps
Generator amps at 80.6°F (27°C) 93 amps at 606 rpm (min) to 160 amps at 2, 020 rpm (max)
Generator pulley ratio 2.97:1
Generator pulley replaceable No
Generator pulley type Solid
Voltage regulator type Electronic internal with generator
6.2L V8 - Optional Extra Heavy Duty 
Rating 200 amps
Generator amps at 80.6°F (27°C) 130 amps at 606 rpm (min) to 207 amps at 2, 020 rpm (max)
Generator pulley ratio 2.97:1
Generator pulley replaceable No
Generator pulley type Solid
Voltage regulator type Electronic internal with generator
6.2L V8 - Snowplow and Camper Package 
Rating 240 amps
Generator amps at 80.6°F (27°C) 132 amps at 606 rpm (min) to 240 amps at 2, 020 rpm (max)
Generator pulley ratio 2.97:1
Generator pulley replaceable No
Generator pulley type Solid
Voltage regulator type Electronic internal with generator
6.7L Power Stroke Diesel - Primary Base Heavy Duty and Vehicles without Ambulance and Fire Engine Package 
Rating 175 amps
Generator amps at 80.6°F (27°C) 115 amps at 583 rpm (min) to 175 amps at 1, 941 rpm (max)
Generator pulley ratio 3.09:1
Generator pulley replaceable No
Generator pulley type Solid
Voltage regulator type Electronic internal with generator
6.7L Power Stroke Diesel - Primary Base Extra Heavy Duty and Vehicles with Ambulance and Fire Engine Package 
Rating 240 amps
Generator amps at 80.6°F (27°C) 132 amps at 583 rpm (min) to 240 amps at 1, 941 rpm (max)
Generator pulley ratio 3.09:1
Generator pulley replaceable No
Generator pulley type Solid
Voltage regulator type Electronic internal with generator
6.7L Power Stroke Diesel - Secondary, if Equipped 
Rating 157 amps
Generator amps at 80.6°F (27°C) 93 amps at 647 rpm (min) to 160 amps at 2, 158 rpm (max)
Generator pulley ratio 2.78:1
Generator pulley replaceable No
Generator pulley type Solid
Voltage regulator type Electronic internal with generator
7.3L 2V DEVCT V8 - Primary 
Rating 240 amps
Generator amps at 80.6°F (27°C) 128 amps at 586 rpm (min) to 240 amps at 1, 986 rpm (max)
Generator pulley ratio 3.03:1
Generator pulley replaceable No
Generator pulley type Solid
Voltage regulator type Electronic internal with generator
7.3L 2V DEVCT V8 - Secondary, if Equipped 
Rating 157 amps
Generator amps at 80.6°F (27°C) 81 amps at 586 rpm (min) to 161 amps at 1, 986 rpm (max)
Generator pulley ratio 2.81:1
Generator pulley replaceable No
Generator pulley type Solid
Voltage regulator type Electronic internal with generator