LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2017 >> Transit-350 HD Base, Van Cargo Extended, 3.2L Eng VIN V >> Repair and Diagnosis >> Engine Performance >> Mode 6 >> Mode 6 - 2017-18 Ford - Diesel >> Comprehensive Component Monitor - Transmission >> Transmission Outputs

Transmission Outputs

TRANSMISSION SOLENOID POWER CONTROL (TSPC - PROVIDES POWER TO ALL TRANSMISSION SOLENOIDS

DTCs P0657 - TSPC1 fault, impacts SSA, SSC, SSE
P2669 - TSPC2 fault, impacts SSB, SSD, TCC and LPC
Monitoring Execution Electrical - Continuous
Monitor Sequence Disables individual solenoid circuit fault detection if either above DTC sets and power is removed from all solenoids (one relay, removes power from both TSPC1 and TSPC2 wires)
SHIFT SOLENOID CHECK OPERATION

DTCs SS A - 
Electrical:
P0750 (Open), P0973 (short to ground), P0974 (short to power)
Functional:
P0751 (stuck off), P0752 (stuck on)
SS B - 
Electrical:
P0755 (Open), P0976 (short to ground), P0977 (short to power)
Functional:
P0756 (stuck off), P0757 (stuck on)
SS C - 
Electrical:
P0760 (Open), P0979 (short to ground), P0980 (short to power)
Functional:
P0761 (stuck off), P0762 (stuck on)
SS D - 
Electrical:
P0765 (Open), P0982 (short to ground), P0983 (short to power)
Functional:
P0766 (stuck off), P0767 (stuck on)
SS E - 
Electrical:
P0770 (Open), P0985 (short to ground), P0986 (short to power)
Functional:
P0771 (stuck off), P0772 (stuck on)
Monitor Execution Electrical - Continuous, Functional - Continuous
Monitor Sequence None
Sensors OK TRS, TSS and OSS ok for functional diagnostics
Monitoring Duration 0.5 to 5 seconds for electrical checks, 3 clutch failed to apply (stuck off) or release (stuck on) events for functional check
TYPICAL SHIFT SOLENOID MECHANICAL FUNCTIONAL CHECK ENTRY CONDITIONS

Entry Conditions (with turbine speed)  Minimum  Maximum 
Gear Ratio Calculated Each Gear
Throttle Position Positive Drive Torque
TYPICAL SHIFT SOLENOID MECHANICAL FUNCTIONAL CHECK ENTRY CONDITIONS

Entry Conditions (without turbine speed)  Minimum  Maximum 
Rpm drop is obtained each shift  
Throttle position positive drive torque  
TYPICAL SHIFT SOLENOID MALFUNCTION THRESHOLDS

Electrical circuit check: Output driver feedback indicates an open, short to ground or open circuit for 0.5 - 5.0 seconds
GEAR RATIO CHECK OPERATION

DTCs P0731 - incorrect gear 1 ratio
P0732 - incorrect gear 2 ratio
P0733 - incorrect gear 3 ratio
P0734 - incorrect gear 4 ratio
P0735 - incorrect gear 5 ratio
P0729 - incorrect gear 6 ratio
P0736 - incorrect reverse ratio 6
Monitor Execution Continuous, in each gear
Monitor Sequence None
Sensors OK TSS, OSS, wheel speed
Monitoring Duration 12 seconds
TYPICAL FORWARD GEAR RATIO CHECK ENTRY CONDITIONS

Entry Conditions  Minimum  Maximum 
Gear selector position forward range,
> 8 seconds
 
Engine Torque 100 NM  
Throttle position 10%  
Not shifting >0.5 seconds  
Engine/input Speed 550 rpm  
Output Shaft Speed 250 rpm 1350 rpm
TYPICAL NEUTRAL GEAR RATIO CHECK ENTRY CONDITIONS

Entry Conditions  Minimum  Maximum 
Gear selector position forward range,
> 1 second
 
Absolute value of Engine rpm - Turbine rpm   150 rpm
Output Shaft Speed   500 rpm
TYPICAL GEAR RATIO MALFUNCTION THRESHOLDS

Forward gear check: > 20% error in commanded ratio for > 12 seconds
TYPICAL SHIFT COMPLETION CHECK ENTRY CONDITIONS

Entry Conditions  Minimum  Maximum 
Gear selector position forward range  
Transmission Fluid Temp 50 °F  
Engine/input Speed 1200 rpm  
Output Shaft Speed 256 rpm  
TYPICAL SHIFT COMPLETION MALFUNCTION THRESHOLDS

Up-shift rpm check: rpm does not drop by > 30 rpm
Down-shift rpm check: rpm does not increase by > 30 rpm
Up-shift rpm check: rpm increases (flares) by > 300 rpm
TORQUE CONVERTER CLUTCH CHECK OPERATION

DTCs Electrical: 
P0740 (open), P0742 (short to ground), P0744 (short to power)
Functional: 
P0741 (stuck off), P2758 (stuck on)
NOTE: P2758 is non-MIL, all other TCC DTC's are MIL
Monitor Execution electrical - continuous,
mechanical - TCC fails to apply 3 times (stuck off) or fails to release 3 times (stuck on)
Monitor Sequence None
Sensors OK TSS, OSS
Monitoring Duration Electrical - 5 seconds, Functional - 3 lock-up or release events
TYPICAL TCC MECHANICAL FUNCTIONAL CHECK STUCK OFF ENTRY CONDITIONS

Entry Conditions  Minimum  Maximum 
Throttle Position steady  
Engine Torque positive drive torque  
Transmission Fluid Temp 70 °F 225 °F
Commanded TCC pressure (0 rpm slip) 55 psi none
Not shifting    
TYPICAL TCC MALFUNCTION THRESHOLDS

Electrical circuit check: Output driver feedback circuit does not match commanded driver state for 0.5 - 5.0 seconds
Mechanical check, stuck off: Slip across torque converter > 100 for 3 seconds after each of 3 lock events
Mechanical check, stuck on: Slip across torque converter < 20 rpm with converter commanded off in at least 3 different gears
PRESSURE CONTROL SOLENOID CHECK OPERATION

DTCs P0960, P0962, P0963 - PC A opens/shorts
P0961 - PC A current range
Monitor Execution Continuous
Monitor Sequence None
Sensors OK  
Monitoring Duration Electrical: 5 seconds,
TYPICAL PRESSURE CONTROL SOLENOID MECHANICAL FUNCTIONAL CHECK ENTRY CONDITIONS

Entry Conditions  Minimum  Maximum 
Gear ratio calculated each gear  
Transmission Fluid Temperature 70 °F 225 °F
Throttle Position positive drive torque  
TYPICAL PRESSURE CONTROL SOLENOID MALFUNCTION THRESHOLDS

Electrical circuit check: Output driver feedback circuit does not match commanded driver state for 0.5 - 5.0 seconds
Electrical current check: Feedback current out of range for 0.5 seconds