Def System Pressure Control
DEF pressure is maintained via feedback knowledge of sensed pressure. Pressure control is closed loop based on the voltage of the DEF pressure sensor. If a pressure increase is desired, the reductant pump motor speed is increased by increasing the PWM output. Pressure decreases are analogous; as the system has a backflow throttle, pressure will decrease to 0 unless the pump motor in run continuously. Once the set point pressure (500 kPa) is reached the following diagnostics are enabled.
| DTCs | P20E8 - Reductant Pressure Too Low P20E9 - Reductant Pressure Too High |
| Monitor Execution | Continuous |
| Monitor Sequence | P20E8 & P20E9 are inhibited by active P204b, P204C or P204D codes |
| Sensors/Actuators OK | reductant pump pressure sensor, reductant pump motor, reductant injector |
| Monitoring Duration | > 10 sec (resp. > 60 sec, see below) |
| Entry Condition | Minimum | Maximum |
| DEF system pressure in closed loop control previously | True |
| P20E8: < 400 kPa for 60 sec respectively < 300 kPa for 10 sec P20E9: > 650 kPa for 10 sec respectively > 790 kPa for 1 sec |
| DTCs | P20FE - Reductant Metering Unit Performance P20FF - Reductant Control Module Performance |
| Monitor Execution | Continuous |
| Monitor Sequence | P007C, P007D - P20FE |
| Sensors/Actuators OK | CACT1 (P007C, P007D) |
| Monitoring Duration | P20FE - 5 sec, P20FF - continuously |
| Entry Condition | Minimum | Maximum |
| P20FE: | ||
| Engine Off Time | 6 hrs | |
| CAC Downstream Temperature | -20 deg C | 80 deg C |
| P20FE: If difference between reductant coil temperature and CAC temperature > 20 deg C, code is set. P20FF: Non-volatile memory corruption detected or reductant pump motor controller temperature >130 deg C |
| DTCs | P20A0 - Reductant Purge Control Valve "A" Circuit /Open P20A2 - Reductant Purge Control Valve "A" Circuit Low P20A3 - Reductant Purge Control Valve "A" Circuit High |
| Monitor Execution | Continuous |
| Monitor Sequence | None |
| Sensors/Actuators OK | |
| Monitoring Duration | Continuously |
| P20A0: voltage > 4.9 v P20A2: voltage < 0.1 v P20A3 voltage > 4.9 v |
Reductant pressure is maintained via feedback knowledge of sensed pressure. A set point pressure is determined by engine operating conditions (500 kPa over exhaust backpressure). If a pressure increase is desired, the reductant pump motor speed is increased by increasing the PWM output. Pressure decreases are analogous; as the system has a backflow throttle, pressure will decrease to 0 unless the pump motor in run continuously.
| DTCs | P20E8 (Reductant Pressure Too Low) P20E9 (Reductant Pressure Too high) |
| Monitor Execution | Continuous |
| Monitor Sequence | P204C and P204D must complete before setting P20E8 or P20E9 |
| Sensors/Actuators OK | DEF pump pressure sensor, DEF pump motor, DEF injector |
| Monitoring Duration | > 60 sec |
| Entry Condition | Minimum | Maximum |
| Reductant system pressurized and ready to inject |
| P20E8: < 400 kPa P20E9: > 950 kPa |