Pinpoint Tests Re: REDUCTANT Purge Valve: Introduction
NOTE:
Regeneration may occur during normal operation. During regeneration, diagnostic procedures may display biased values. If a regeneration occurs during diagnostic procedures, allow the process to complete before continuing diagnostics.
This pinpoint test is intended to diagnose the following:
- reductant purge valve
- harness circuits: RDPGC and VPWR
- reductant dosage control module (5H298)
| Pin | Circuit |
|---|---|
| 2 | VPWR (Vehicle Power) |
| 1 | RDPGC (Reductant Purge Control) |
| Pin | Circuit |
|---|---|
| 94 | RDPGC (Reductant Purge Control) |