  1. 1.

    Using a new gasket, install the upper intake manifold and the 7 bolts.
    • Tighten in the sequence shown in 2 stages.
      • Stage 1: Tighten to 10 Nm (89 lb-in).
      • Stage 2: Tighten an additional 45 degrees.
Fig 1: Upper Intake Manifold Tightening Sequence
GFD134062Courtesy of FORD MOTOR COMPANY

  1. 2.

    Install the upper intake manifold support bracket bolt.
    • Tighten to 10 Nm (89 lb-in).
GFD81966Courtesy of FORD MOTOR COMPANY

  1. 3.

    Attach the 2 coolant tube retainers to the upper intake manifold.
GFD81965Courtesy of FORD MOTOR COMPANY

  1. 4.

    Connect the power brake booster vacuum supply hose and crankcase ventilation hose to the upper intake manifold.
GFD81964Courtesy of FORD MOTOR COMPANY

  1. 5.

    Connect the EVAP vapor tube to the EVAP canister vent solenoid. For additional information, refer to Fuel System General Information .
    • Attach the EVAP vapor tube to the 2 retainers.
GFD81963Courtesy of FORD MOTOR COMPANY

  1. 6.

    Connect the MAPT electrical connector.
    • Attach the wiring harness pin-type retainer to the upper intake manifold.
GFD134060Courtesy of FORD MOTOR COMPANY

  1. 7.

    Connect the EVAP canister vent solenoid and throttle body electrical connectors.
    • Attach the wiring harness pin-type retainer to the upper intake manifold.
GFD81962Courtesy of FORD MOTOR COMPANY

  1. 8.

    Install the ACL outlet pipe. For additional information, refer to Intake Air Distribution and Filtering .