P0400 - EGR A Flow

DTC DESCRIPTION P0400 - EGR A FLOW

Description:  The electric exhaust gas recirculation (EEGR) system is monitored once per drive cycle at high and low load conditions. This DTC sets when the PCM detects EGR flow is less or greater than expected.
Possible Causes: 
  • EEGR valve stuck open or closed
  • EEGR connector not seated correctly
  • EEGR stepper motor
  • VPWR circuit open
  • EGRMC circuit open
  • EGRMC circuit short to ground
  • EGRMC circuit short to voltage
  • Vacuum signal to manifold absolute pressure (MAP) restricted or leaking
  • Mass airflow (MAF) sensor signal erroneous
  • Carbon build up in the EEGR valve seat area
Diagnostic Aids:  The following sensors input data to the PCM for correct operation of the EEGR system: cylinder head temperature (CHT) sensor, intake air temperature (IAT) sensor, MAF sensor, throttle position (TP) sensor, MAP sensor. Diagnose any DTC relating to these sensors prior to addressing this DTC.
Application  Key On Engine Off  Key On Engine Running  Continuous Memory 
All GO to Pinpoint Test KD .