Pinpoint Test L : B10B5:11, B10B5:15, B10B6:11, B10B6:15: Notes
Refer to MANUAL CLIMATE CONTROL SYSTEM for schematic and connector information.
Normal Operation and Fault Conditions
The air discharge temperature sensors contains a thermistor. The sensor varies its resistance with the temperature. As the temperature rises, the resistance falls. As the temperature falls, the resistance rises.
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| B10B5:11 | Left Panel Air Discharge Temperature: Circuit Short To Ground | This DTC sets when the FCIM senses erratic voltages from the left panel air discharge temperature sensor. |
| B10B5:15 | Left Panel Air Discharge Temperature: Circuit Short To Battery or Open | This DTC sets when the FCIM senses erratic voltages from the left panel air discharge temperature sensor. |
| B10B6:11 | Left Floor Air Discharge Temperature: Circuit Short To Ground | This DTC sets when the FCIM senses erratic voltages from the left floor air discharge temperature sensor. |
| B10B6:15 | Left Floor Air Discharge Temperature: Circuit Short To Battery or Open | This DTC sets when the FCIM senses erratic voltages from the left floor air discharge temperature sensor. |
Possible Sources
- Wiring, terminals or connectors
- Air discharge temperature sensor(s)
- FCIM