Threshold OVERBOOST Monitoring (2014)

The pressure-based overboost diagnostic is adequate for detecting a turbo stuck in the closed position on the dyno cert application, however with a stuck turbocharger on the chassis cert application the pressure deviation is not significant because of wastegate operation. With a wastegate in place, the closed loop boost pressure governor is capable of maintaining the desired boost pressure with the turbocharger stuck in a closed position. The functional overboost monitor is not able to detect this, so an additional boost system diagnostic is utilized since desired pressure is maintained in the system.v

The closed loop boost pressure controller controls boost based predicted control targets and anticipated turbocharger position. The output value, in percentage, indicates the "control effort" required to maintain the desired boost pressure. With a turbocharger stuck in the closed position, the control effort decreases. There is a temperature entry condition, torque entry conditions, a steady state requirement on manifold pressure, an exhaust temperature entry condition, and a threshold map. If the threshold is exceeded for 4 seconds, a fault is detected.

THRESHOLD OVERBOOST MONITOR

DTCs P0234 - Turbocharger/Supercharger "A" Overboost Condition
Monitor Execution Continuous
Monitor Sequence None
Sensors OK ECT, MAP, MAF
Typical Monitoring Duration 4 sec
TYPICAL THRESHOLD OVERBOOST ENTRY CONDITIONS

Entry Condition Minimum Maximum
Engine Torque 200 Nm 700 Nm
Engine Coolant Temperature -7 deg C  
Ambient Air Temperature -7 deg C  
Barometric Pressure 75 kPa 110 kPa
MAP Steady State Pressure   100 kPa
TOxiCatUs Temperature 99 deg C  
Mass Air Flow   1300 kg/h
Not in Cold Start Warm-up Mode  
Regeneration Status None
TYPICAL THRESHOLD OVERBOOST MONITOR MALFUNCTION THRESHOLDS

If control effort percent is < threshold map for 4 seconds a fault is detected.
TYPICAL THRESHOLD OVERBOOST MONITOR (P0234) THRESHOLD MAP

RPM/TRQ 600 750 1000 1200 1600 2000 2250 2500 2750 3000 3250 3500
0 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43
100 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43
150 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43
200 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43
250 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43
300 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43
350 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43
400 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43
450 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43
500 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43
600 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43
700 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43 -43