GENERAL SPECIFICATIONS

Item Specification
1.5L EcoBoost and 1.6L EcoBoost - 150A (base) 
Generator pulley ratio 2.49:1
Rating 90 amps at 700 RPM (min) to 155 amps at 2, 400 RPM (max)
Voltage regulator type Electronic internal with generator
1.5L EcoBoost and 1.6L EcoBoost - 175A (optional) 
Generator pulley ratio 2.49:1
Rating 120 amps at 700 RPM (min) to 180 amps at 2, 400 RPM (max)
Voltage regulator type Electronic internal with generator
2.0L EcoBoost - 150A (base) 
Generator pulley ratio 2.79:1
Rating 90 amps at 650 RPM (min) to 160 amps at 2, 200 RPM (max)
Voltage regulator type Electronic internal with generator
2.0L EcoBoost - 175A (optional) 
Generator pulley ratio 2.47:1
Rating 120 amps at 700 RPM (min) to 180 amps at 2, 400 RPM (max)
Voltage regulator type Electronic internal with generator
2.0L EcoBoost - 200A (optional) 
Generator pulley ratio 2.47:1
Rating 130 amps at 700 RPM (min) to 200 amps at 2, 400 RPM (max)
Voltage regulator type Electronic internal with generator
2.5L Duratec - 150A (base) 
Generator pulley ratio 2.79:1
Rating 90 amps at 650 RPM (min) to 160 amps at 2, 200 RPM (max)
Voltage regulator type Electronic internal with generator
2.5L Duratec - 175A (optional) 
Generator pulley ratio 2.47:1
Rating 120 amps at 700 RPM (min) to 180 amps at 2, 400 RPM (max)
Voltage regulator type Electronic internal with generator