Solenoid Operation Chart
SOLENOID OPERATION CHART
| Base Selector Lever Position | PCM Commanded Gear | Shift Solenoid | TCC (VFS) NL | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| SSA (VFS) NL (CB 1, 2, 3, 4) | SSB (VFS) NH (3, 5, R) | SSC (VFS) NL (CB 2, 6) | SSD (VFS) NH (CB L, R/C 4, 5, 6) | SSE (On/Off) NC | |||||||
| P | P | Off | On | Off | Off | On | Off | ||||
| R | R | Off | Off | Off | Off | On | Off | ||||
| N | N | Off | On | Off | Off | On | Off | ||||
| D | 1 | On | On | Off | Off (1) | On (2) | Off | ||||
| 2 | On | On | On | On | Off | Off | |||||
| 3 | On | Off | Off | On | Off | Off | |||||
| 4 | On | On | Off | Off | Off | On/Off | |||||
| 5 | Off | Off | Off | Off | Off | On/Off | |||||
| 6 | Off | On | On | Off | Off | On/Off | |||||
| L | 1 | On | On | Off | Off | On | Off | ||||
CB = Clutch brake NC = Normally closed NH = Normally high NL = Normally low |
|||||||||||