LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2009 >> Explorer 4.0 E, RWD >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Automatic Transmission - 5R55S >> Diagnostic Tests >> Output State Control (OSC) Mode >> PCA, PCB, PCC in Bench Mode

PCA, PCB, PCC in Bench Mode

WARNING: Block all wheels, set the parking brake and firmly apply the service brake to reduce the risk of vehicle movement during this procedure. Failure to follow these instructions may result in serious personal injury.

The Bench Mode is also used to test the functionality of the transmission electronic pressure control. During Bench Mode, the PCx solenoids can be commanded in increments of 15 psi from 0 to 90 psi and 90 to 0 psi.

The line pressure tap is used to verify output pressure from PC A or PC B by turning either one off while verifying the output from the other solenoid. The second pressure tap is used to verify the output from the PC C solenoid.

The OSC functions for the parameter PCx allows the technician to choose the following options:

OSC "PCx" Bench Mode should ONLY be operated to check PRESSURE FUNCTIONALITY using an installed pressure gauge (300 psi) when:

OSC "PCx" Bench Mode should ONLY be operated to complete PCx SOLENOID CIRCUIT PINPOINT TESTS when:

OSC Command Values: