LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2009 >> Explorer 4.0 E, RWD >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Automatic Transmission - 5R55S >> Diagnostic Tests >> Diagnostic Parameters Identification (PID) Chart >> Using Output State Control and Accessing PIDs

Using Output State Control and Accessing PIDs

To confirm that the output state control value was sent by the scan tool and the PCM has accepted the output state control substitution, a corresponding PID for each output state control parameter must be monitored. Additional PIDs should be monitored to help the technician adequately diagnose the transmission.

To confirm that the output state control substitution occurred, select the output state control value and monitor the corresponding PID value. If no ERROR MESSAGE was received and the value of the corresponding PID is the same as the value sent from output state control, then the output state control substitution was successful.

PID Name Description Units
APP Accelerator Pedal Position (APP) Percent
APP1 APP 1 Volts 0 to 5
APP2 APP 2 Volts 0 to 5
APP3 APP 3 Volts 0 to 5
BOO Brake On/Off On/Off
BPA Brake pedal applied On/Off
CPP/PNP Clutch Pedal Position (CPP)/park neutral position Neutral/Drive
DTC CMT DTC Count Number
ECT Engine Coolant Temperature (ECT) Temp/Voltage (0-5)
ETC_ACT Electronic Throttle Control Actual Angle (0-100 degrees)
ETC_DSD Electronic Throttle Control (ETC) Desired Angle (0-100 degrees)
GEAR# Gear Commanded by module 1, 2, 3, 4 or 5
GEAR_MAX Highest gear available for vehicle speed 1, 2, 3, 4 or 5
GEAR_RAT Gear ratio Ratio (0-5:1)
HRSH_SHFT# Firm shift On/Off
IAT Intake Air Temperature (IAT) Volts 0-5/Temp
ISS_SRC Intermediate shaft speed RPM 0-5,000
LOAD Engine load Percent 0-100
OSSFM Output Shaft Speed (OSS) failure mode Fault/No Fault
OSS_SRC Unfiltered output speed failure mode RPM 0-5,000
PCA Pressure Control Solenoid A (PCA) (solenoid commanded pressure) kPa/psi 0-3447/0-500
PCA AMP PCA current Current 0-1 amp
PCA_F PCA fault Fault/No Fault
PCB# Pressure Control Solenoid B (PCB) (solenoid commanded pressure) kPa/psi 0-3447/0-500
PCB AMP PCB current Current 0-1 amp
PCB_F PCB fault Fault/No Fault
PCC# Pressure Control Solenoid C (PCC) (solenoid commanded pressure) kPa/psi 0-3447/0-500
PCC AMP PCC current Current 0-1 amp
PCC_F PCC fault Fault/No Fault
PCFM Pressure control failure mode Fault/No Fault
RPM# Engine revolutions per minute RPM 0-5,000
SCCS Speed control commanded switch Volts 0-10/Mode
SHFT_TYPE Shift type (selector lever range) PRND321
SSA/SS1# Shift Solenoid A (SSA) command On/Off
SSA/SS1F SSA fault Fault/No Fault
SSB/SS2# Shift Solenoid B (SSB) command On/Off
SSB/SS2F SSB fault Fault/No Fault
SSC/SS3# Shift Solenoid C (SSC) command On/Off
SSC/SS3F SSC fault Fault/No Fault
SSD/SS4# Shift Solenoid D (SSD) command On/Off
SSD/SS4F SSD fault Fault/No Fault
TCC# Torque Converter Clutch (TCC) modulated Mode 0-100% On/Off
TCCFM Torque convertor unlocking due to slipping Fault/No Fault
TCC_F TCC fault Fault/No Fault
TCC_OT Transmission over temperature Fault/No Fault
TCC_RAT Transmission slip ratio (engine speed compared with turbine shaft speed) Ratio 0-5
TCIL Transmission Control Indicator Lamp (TCIL) On/Off
TCS Transmission Control Switch (TCS) Overdrive (O/D) cancel/hold switch On/Off
TCSLIP_ABSL Absolute value of slip RPM 0-2,000
TCCSLIPP ACT Torque convertor slip actual RPM (-100-4,000)
TC_SLIPDSD Torque convertor slip desired RPM 0-2,000
TFT Transmission Fluid Temperature (TFT) Volts 0-5/Temp
TFT_F TFT status Fault/No Fault
TORQUE Net engine torque Newton Meter -150/500
TP1 Throttle Position (TP) sensor 1 Volts 0-5
TP2 TP sensor 2 Volts 0-5
TR Transmission Range (TR) switch Mode PRNOverdrive 321
TR1 TR 1 Open/Closed
TR2 TR 2 Open/Closed
TR3 TR 3 Open/Closed
TR_V TR 3 Volts 0-5
TR4 TR 4 Open/Closed
TRAN_RAT Transmission gear ratio Ratio (0-6:1)
TRIP CNT Number of On-Board Diagnostic (OBD) trips completed Number
TR_F TR status Fault/No Fault
TSS Turbine Shaft Speed (TSS) RPM 0-5,000
TSSFM TSS failure mode Fault/No Fault
TSS_SRC Unfiltered TSS RPM 0-5,000
VPWR Module supply voltage Volts 10-16V
VSS Vehicle Speed Sensor (VSS) SPD 0-128 km/h 0-80 mph
VSS_FM VSS signal status Fault/No Fault