Solenoid Operation Chart - Converter Disengaged
SOLENOID OPERATION CHART - CONVERTER DISENGAGED
| Base Gearshift Selector Position | PCM Commanded Gear | 4F27E Solenoid States - Converter Engaged | |||||
|---|---|---|---|---|---|---|---|
| SSA | SSB | SSC | SSD | SSE | PCA | ||
| P/N | P/N | On | Off | Not fed | Not fed | Not fed | - |
| R | R | Off | Off | Not fed | Off | Not fed | - |
| D | 1 | Off | Off | Off | On | On | - |
| - | 1 (M) | On | On | Off | Off | On | - |
| - | 2 | Off | Off | Off | Off | On | - |
| - | 3 | Off | Off | Off | Off | Off | - |
| - | 4 | On | Off | On | Off | Off | - |