Pinpoint Test C: The Control Linkage Is Binding
- C1 CHECK THE SHIFT CONTROL COMPONENTS FOR DAMAGE
WARNING:
If equipped with fire suppression system, depower the system. For important safety warnings and procedures, refer to FIRE SUPPRESSION SYSTEM
.
- With the vehicle in NEUTRAL, position it on a hoist. For additional information, refer to JACKING AND LIFTING
.
- Gain access to the shift control components.
- Key in ACCESSORY position.
- Apply the brake pedal.
- Observe all shift control components while attempting to shift the gearshift lever through all ranges.
- Are any of the components damaged?
- Yes
: REPAIR as necessary. REINSTALL all components. TEST the system for normal operation. If equipped with fire suppression system, GO to C4.
- No
: GO to C2.
- C2 CHECK THE SHIFT CONTROL COMPONENT OPERATION WITH THE SHIFT CABLE DISCONNECTED FROM THE TRANSMISSION
- Key in OFF position.
- Raise and support the vehicle. Refer to JACKING AND LIFTING
.
- Disconnect the shift cable from the manual control lever.
- Lower the vehicle.
- Key in ACCESSORY position.
- Apply the brake pedal.
- Observe the shift control components while attempting to shift the gearshift lever through all ranges.
- Do the components move fluidly through all ranges?
- C3 CHECK THE SHIFT CONTROL COMPONENT OPERATION WITH THE SHIFT CABLE DISCONNECTED FROM THE STEERING COLUMN
- Key in OFF position.
- Disconnect the shift cable from the transmission selector lever arm and support.
- Key in ACCESSORY position.
- Apply the brake pedal.
- Observe the shift control components while attempting to shift the gearshift lever through all ranges.
- Do the components move fluidly through all ranges?
- C4 REPOWER THE FIRE SUPPRESSION SYSTEM
WARNING:
If equipped with fire suppression system, repower the system. For important safety warnings and procedures, refer to FIRE SUPPRESSION SYSTEM
.
- Verify that the fire suppression system is repowered. For additional information, refer to FIRE SUPPRESSION SYSTEM
.
- Is the fire suppression system repowered?
- Yes
: Fire suppression system repowering is complete.
- No
: REFER to FIRE SUPPRESSION SYSTEM
for fire suppression system depowering and repowering procedure.