Test E: Warning Indicator Off With Ignition On
- Check Charging System Warning Indicator
Turn the ignition off. Disconnect generator 3-pin connector. With the engine off, connect a fused jumper wire (15A) between the generator connector terminal No.1, GEN MON circuit (White/Red wire) and ground. See Figure
. Turn ignition on. Is the charging system warning indicator illuminated? If yes, install a new generator. See GENERATOR
under REMOVAL & INSTALLATION. Test the system for normal operation. If no, see appropriate ANALOG INSTRUMENT PANEL article in ACCESSORIES & EQUIPMENT for diagnosis and testing of the instrument cluster.