GENERATOR SPECIFICATIONS

Application Specification
Generator Amperage Rating
2.3L 110 Amps
3.0L & 4.0L Built Before 11/2003, Without Tremor Audio 95 Amps
3.0L & 4.0L Built After 11/2003 Or With Tremor Audio 115 Amps
Load Test (1)(2)
95 Amp Minimum 38 Amp
110 Amp Minimum 65 Amp
115 Amp Minimum 70 Amp
No-Load Test (1) 13-15 Volts
(1) All tests are performed with engine running at 2000 RPM and all accessories off.
(2) Adjust tester load bank to determine generator output.