Drive Cycle Preparation
NOTE:
For best results, follow each of the following steps as accurately as possible.
- Install the scan tool. Turn the key ON with the engine OFF. Cycle the key off, then on. Select the appropriate vehicle and engine qualifier. Clear all diagnostic trouble codes (DTCs) and carry out a PCM reset.
- Begin to monitor the following PIDs: ECT, EVAPDC, FLI (if available) and TP MODE. Press Diagnostic Data Link, PCM, PID/Data monitor and record, press trigger to select each PID, then start.
- Start the engine without returning the key to the OFF position.
NOTE:
This step bypasses the engine soak timer and resets OBD II monitor status.