Starter No-Load Test
- Remove starter motor. See STARTER MOTOR under REMOVAL & INSTALLATION. Connect remote starter switch between positive battery terminal and starter motor solenoid terminal "S". See Figure . Jumper starter motor "B" terminal to positive battery post. Connect charging/starting system tester according to manufacturer's instructions. Ensure battery and starter motor are grounded.
- Engage remote starter switch. Starter should eject starter drive and turn smoothly. Voltmeter should indicate 11 volts or more, and ammeter should indicate 60-80 amps. If voltage is lower or current is higher than specification, replace starter motor. See STARTER MOTOR under REMOVAL & INSTALLATION.