Test D: Warning Indicator Is Off With Ignition On
Turn ignition on. Disconnect generator 3-pin connector. Connect a fused (15-amp) jumper wire between generator connector terminal "I" (Light Green/Red wire) and ground. See Figure . If warning indicator is on, replace voltage regulator. See VOLTAGE REGULATOR under REMOVAL & INSTALLATION. If warning indicator is not on, see appropriate ANALOG INSTRUMENT PANELS article in ACCESSORIES & EQUIPMENT.