LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Contour SVT >> Repair and Diagnosis >> External Pages >> Different car >> Section 57 (Charging System - (Generator & Regulators)) >> Generator Specifications

Generator Specifications

WARNING: This page is about a different car, the 2003 Ford Ranger and 2002 Ford Ranger. However, it is still accessible from the selected car via links, so may be relevant.
GENERATOR SPECIFICATIONS

Application Specification
Ranger
Generator Amperage Rating
2.3L & 4.0L 115 Amps
3.0L 90 Amps
Load Test (1)
With Tester Load (2) (3)
Without Tester Load (4) (5)
No-Load Test (1)(2) 13-15 Volts
(1) All tests are performed with engine running at 2000 RPM.
(2) All accessories off.
(3) Adjust tester load bank to determine generator output.
(4) Perform this test with engine running, A/C on, blower motor on high speed, and headlamps on high beam.
(5) With accessories on, voltage should increase a minimum of 0.5 volt above base voltage.