  1. Connect New Generation Star (NGS) tester to Data Link Connector (DLC), if not already connected. Select vehicle to be tested from NGS tester menu.
  2. Turn ignition on. Rotate dial on NGS tester to menu item DIAGNOSTIC DATA LINK and press trigger. A test will be performed on the BUS (circuits No. 914 and 915) for the module communications network and the ISO 9141 communication network (circuit No. 70). This is the Light Blue/White wire that is between terminal No. 7 on DLC, air bag diagnostic monitor and 4WABS module.
  3. If NGS tester displays CKT 914 (+) = SYSTEM PASSED and CKT 915 (-) = SYSTEM PASSED, module communications network is okay. If NGS tester displays CKT 70 = SYSTEM PASSED, ISO 9141 communication network is operating properly. Return to article that directed you here and continue diagnosis.
  4. If NGS tester does not display CKT 914 (+) = SYSTEM PASSED, CKT 915 (-) = SYSTEM PASSED and CKT 70 = SYSTEM PASSED, perform the following as applicable: