LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 1998 >> Crown Victoria Base, 4.6 W >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Tests W/Codes - Gasoline 4.6L >> Additional System Functions >> Drive Cycles >> EGR Monitor Repair Verification Drive Cycle

EGR Monitor Repair Verification Drive Cycle

Ambient air temperature or IAT PID must read a minimum of 32°F (0°C) to initiate EGR monitor. Perform VEHICLE PREPARATION  . Drive vehicle for 5 minutes in stop and go traffic with a minimum of 2 idle periods (30 seconds each). Accelerate vehicle to 45 MPH. Maintain speed for one minute. Stop vehicle and repeat QUICK TEST  .