Taurus 3.4L SHO
- Slowly discharge A/C system, using approved refrigerant recovery/recycling equipment. Remove A/C compressor. Drain as much compressor oil from suction and discharge ports as possible. Rotate compressor shaft 6-8 revolutions by hand, while pouring oil from ports. Collect oil in a clean container and measure amount drained. DO NOT reuse old refrigerant oil.
- If amount drained is 3-5 ounces, add amount drained plus one ounce of NEW refrigerant oil to compressor. If amount drained is more than 5 ounces, add the same amount that was drained from compressor. If amount drained is less than 3 ounces, add 3 ounces to compressor. See SANDEN SCROLL COMPONENT REFRIGERANT OIL CAPACITIES (TAURUS 3.4L SHO)
table. Add NEW refrigerant oil through suction port.
- Use NEW "O" rings on refrigerant lines. Install A/C compressor. Perform leak test. Evacuate and charge system. Ensure A/C system is operating properly.
SANDEN SCROLL COMPONENT REFRIGERANT OIL CAPACITIES TAURUS 3.4L SHO
| Component |
Ounces |
| Accumulator |
|
| Condenser |
1.0 |
| Evaporator |
3.0 |
| Other Components |
2.0 |