Rotor Open Or Short Circuit Test

  1. Set ohmmeter on X1 scale. Measure resistance between slip rings. Resistance should be 2.5-3.6 ohms.
  2. Higher resistance indicates damaged slip ring solder connection or broken wire. Lower resistance indicates shorted wire or slip ring. Replace rotor if it does not meet specification.