LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 1994 >> Explorer 2D Utility, RWD, Automatic >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - System/Component Tests >> Emission Systems & Sub-Systems >> Secondary Air Injection >> Dual Air Control Solenoid Valves

Dual Air Control Solenoid Valves

Function of each valve can be determined by externally energizing valve with vacuum lines attached. Check resistance of each solenoid. Resistance should be 51-108 ohms when checked at coil terminals. If resistance is not 51-108 ohms, solenoid should be replaced.