Control Assembly Test
- Disconnect electrical connector from switch. Connect positive lead of ohmmeter to switch terminal of Gray/Light Blue wire. Connect negative lead of ohmmeter to switch terminal of Black wire. Continuity should exist.
- Connect ohmmeter to switch terminal of Brown/Light Blue wire and switch terminal of Purple/Orange wire. Continuity should exist. If continuity does not exist in either test, replace switch.