Db-7 Hydraulic Ground Check
Ensure ignition is off. Set ohmmeter to 200-ohm scale. Measure resistance between hydraulic control unit Black wire and ground. If resistance is less than 5 ohms, replace hydraulic control unit. If resistance is greater than 5 ohms, repair Black ground wire. NOTE: Check hydraulic pump motor operation.