LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 1989 >> Probe GL, Automatic >> Repair and Diagnosis >> Electrical >> Gauges >> Instrument Panel - Analog >> Testing >> Voltmeter Inoperative

Voltmeter Inoperative

  1. Check 15-amp instrument cluster fuse in interior fuse panel. Fuse panel is located just above left kick panel. If fuse is okay, go to INSTRUMENT CLUSTER SUPPLY CHECK  .
  2. If fuse is blown, replace fuse. If fuse blows again, check for shorts to ground in Black/Yellow wire at instrument cluster 18-pin connector. Repair as necessary.