Normally Closed Valve
Valve may be mounted on air pump or in-line. A normally closed valve supplies air to exhaust system with medium and high applied vacuum signals during normal engine operating temperature, short idles and some accelerations. With low or no vacuum applied, fresh air is dumped through silencer ports of valve or through air pump port. See Fig 1 .