Removal & Installation: Installation
Reverse removal procedure to install with the following exceptions:
- When installing water inlet and discharge pipes, use a pipe sealant with Teflon (D8AZ-19554-A). Install inlet fitting within 5 degrees of vertical, pointing down.
- Always use new gasket between turbocharger and mounting block.
- Use new nuts on turbocharger mounting studs.