Torque Converter Flushing
Whenever transmission has been disassembled to replace worn or damaged parts or because valve body sticks due to foreign material, converter must be cleaned using a mechanically agitated cleaner, such as Rotunda (014-00028). Under no conditions should converter be cleaned by hand agitation using solvent. After converter is removed from cleaner, thoroughly drain solvent through hub. Add approximately 2 qts. (1.9L) clean ATF to converter. Agitate fluid by hand. Thoroughly flush ATF from converter.