Float Level
- Hold air horn upside down at 45° angle with gasket in place. Float tang should rest lightly on inlet needle. Using a drill bit or pin gauge, measure clearance between float toe and air horn casting. See Fig 1 .
- To adjust, remove float assembly and bend float level adjusting tang. DO NOT damage or scratch float tang during adjustment.