Continuous Monitor (Wiggle) Test
NOTE:
Make sure that Self-Test is deactivated. DO NOT
activate Self-Test unless specifically instructed to do so.
- This test monitors ECA inputs for shorts and opens. Self-Test output will be activated when a fault is detected. A detected fault is indicated by a 10.5 volt or greater deflection on VOM. One or both of the following modes may be used to find intermittent fault:
- Key On/Engine Off (KOEO): Self-Test deactivated and ignition switch ON.
- Key On/Engine Running (KOER): Self-test activated. After service code output has finished, DO NOT
turn engine off or deactivate Self-Test. About 2 minutes after code 11 has been displayed, Continuous Monitor test mode will start. It will run until Self-Test is deactivated or engine is turned off.NOTE: An alternate method of entering this test with engine running is to enter KEY ON-ENGINE RUNNING (KOER) SELF-TEST , exit, and re-enter Engine Running test. DO NOT turn engine off.
- Observe VOM while moving, wiggling, and tapping the system harness, connectors, and sensors. If an intermittent condition is created, the monitor will indicate this by storing a service code.
- Perform KEY ON-ENGINE OFF (KOEO) SELF-TEST to retrieve codes. If any codes are indicated, go to proper test as shown in Continuous Test table. If no codes appear, the fault is not in a monitored EEC sensor circuit. EEC testing is complete. Refer to DIAGNOSTICS BY SYMPTOM - TEST X for additional testing information.
NOTE:
Continuous test can only be run once without turning ignition off. DO NOT
miss any of the service codes.