- Remove bottom cover by making a shallow, close cut to bottom outside edge. Use caution not to damage inner shell.
- Remove insulation and check inner shell for damage. If damage is found, entire converter must be replaced.
- If no damage is found, position new insulation into replacement cover. Apply Sealer (8998245) around edge of cover, using extra sealer at front and rear pipe openings.
- Install replacement cover on converter and position retaining channel along edges. Complete the installation by attaching clamps (provided with replacement cover) to both ends of converter.