LEMON Manuals: Even more car manuals for everyone
Home >> Eagle >> 1995 >> Vision ESi >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> A/C-Heater System - Automatic >> Testing >> A/C System Charge Level Test >> Using Manifold Gauge Set

Using Manifold Gauge Set

  1. Attach clamp-on thermocouple to liquid line, as close to condenser outlet as possible. Connect gauge set to high side and low side connectors.
  2. Note discharge pressure and liquid line temperature. Use REFRIGERANT CHARGE LEVEL table to determine if system is undercharged or overcharged.