LEMON Manuals: Even more car manuals for everyone
Home >> Eagle >> 1993 >> Vision ESi >> Repair and Diagnosis (Single Page) >> Body & Frame >> Door Locks >> Keyless Entry System - Remote >> Testing >> Test 36D - Remote Keyless Entry (RKE) Module Problem >> LH Body

LH Body

  1. If problem is with trunk release or warning light, go to TEST 36E of the appropriate TESTS W/CODES - BODY CONTROL COMPUTER article in the ENGINE PERFORMANCE section. See following list. If problem is not with trunk release or warning light, ensure DRB-II door lock test is still active. Disconnect Remote Keyless Entry (RKE) module Black connector. Module is located on top, right side of dashboard.
  2. With DRB-II in voltmeter mode, check voltage on RKE Black connector door unlock relay feed circuit (Pink/Violet wire). If voltage fluctuates from zero volts to less than 10 volts, repair open circuit in Pink/Violet wire. Perform VERIFICATION PROCEDURE VER-1  .
  3. If voltage fluctuates from zero volts to more than 10 volts, use DRB-II to stop door lock test. With DRB-II in ohmmeter mode, check resistance on RKE Black connector ground circuit (Black wire). If resistance is less than 5 ohms, replace RKE module. Perform VERIFICATION PROCEDURE VER-1  . If resistance is more than 5 ohms, repair open circuit in Black wire. Perform VERIFICATION PROCEDURE VER-1  .