AC & AY Bodies
- Using DRB-II, stop door lock actuation test. Remove key from ignition switch. Using DRB-II, read key in ignition switch status. If DRB-II displays CIRCUIT CLOSED, refer to TEST 47A in the appropriate TESTS W/CODES
- BODY CONTROL COMPUTER article in the ENGINE PERFORMANCE section. See following list.
- If DRB-II did not display CIRCUIT CLOSED, put DRB-II in voltmeter mode. Turn ignition off. Disconnect Body Control Module (BCM) Black connector. BCM is located behind right kick panel. Check connector condition, and clean or repair connector as necessary.
- Check voltage on terminal No. 4 (Orange/Violet wire) of BCM Black connector. While observing DRB-II, lock doors using left door lock switch. If voltage is more than 10 volts, replace BCM. Perform VERIFICATION PROCEDURE VER-1
. If voltage is less than 10 volts, check door lock wiring and switch. Repair as necessary. Perform VERIFICATION PROCEDURE VER-1
.