Purge Control System
- Disconnect Red striped vacuum hose from throttle body, plug disconnected nipple. Connect hand vacuum pump to disconnected hose. Start engine. Let Idle.
- With engine temperature 140°F (60°C) or less (cold engine), apply 14 in. Hg. Vacuum should hold. Raise engine speed to 3000 rpm. Vacuum should hold.
- Return to idle. Bring engine temperature to 158°F (70°C) or more (warm engine). Apply 14 in. Hg. Vacuum should hold. Raise engine speed to 3000 rpm (within 3 minutes of starting). Vacuum should not hold.
- After 3 minutes have passed since starting warm engine, apply 14 in. Hg. Vacuum should hold momentarily, then leak down.
NOTE:
If altitude is 7200 feet (2200 meters) or higher, OR intake air temperature 122°F (50°C) or less, vacuum will leak continuously.