2153-Starter Control Signal Interrupted: Notes
For complete wiring diagrams, refer to SYSTEM WIRING DIAGRAMS .
- When Monitored:
With the ignition on and the Starter Relay command off.
- Set Condition:
The Engine Control Module (ECM) detects that the Engine Starter Motor Relay Control circuit open for 1.0 second.
| Possible Causes |
|---|
| ENGINE STARTER MOTOR RELAY CONTROL CIRCUIT SHORTED TO GROUND |
| ENGINE STARTER MOTOR RELAY CONTROL CIRCUIT OPEN OR HIGH RESISTANCE |
| FUSED IGNITION SWITCH OUTPUT (RUN-START) CIRCUIT OPEN OR HIGH RESISTANCE |
| STARTER RELAY |
| ENGINE CONTROL MODULE (ECM) |
Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding. See DTC-Based Diagnostics/MODULE, Engine Control (ECM) - Standard Procedure .