3.7L/4.7L Engine
CAUTION:
When servicing or replacing exhaust system components, disconnect the oxygen sensor connector(s). Allowing the exhaust to hang by the oxygen sensor wires will damage the harness and/or sensor.
- Make sure the catalytic converter pipe is free of burrs.
- Insert the catalytic converter into the exhaust pipe.
- Make sure the alignment tang is fully seated in the alignment slot.
- If other sections of the exhaust system where loosened in removal, refer to that information for the tightening procedures.
- At the catalytic converter-to-extension pipe connection, install the clamp and nuts. Tighten the clamp nuts to 41 N.m (30 ft. lbs.) torque.
- Lower the vehicle.
- Start the engine, inspect for exhaust leaks. Repair exhaust leaks as necessary.
- Check the exhaust system for contact with the body panels. Make the necessary adjustments, if necessary.